#1 2021-06-23 11:18

manmanman
New Member
Registered: 2021-06-23
Posts: 1

Auto switch not work between two conditions

Hello.
I Have a NetSetMan Pro Version 5.0.6 on my windows 10 64 bit.
I have Two Profiles With exact same configuration but only different in gateway like:
Profile 1 : Default Gateway is 192.168.1.1
Profile 2 : Default Gateway is 192.168.2.1
Every thing else is Same.
I have Conditions in two profiles in type of TIME FRAME like
Profile 1 : All Days Selected and Time - From is 11:00 , Time - To is 1:00 (I mean 11 -one hour before mid day-until 1 at morning )
Profile 2 : All Days Selected and Time - From is 1:00 , Time - To is 11:00 (I mean 1 at morning until 11 -one hour before mid day- )
I want it change automatically at this two time point.

All Conditions Must be met with delay 1s are Active for both profile And Enable Auto switch is Checked.
When I Install this software and start it, it was night. Profile 2 Activated Automatically and Every thing is good but Profile 1 Not Activated at 11:00 and I Active it manually And this thins Happens Every Day.
What is Problem?

Offline

#2 2021-06-28 15:39

NetSetMan Support
Administrator
Registered: 2005-08-06
Posts: 1,878

Re: Auto switch not work between two conditions

The time frame is defined per day. This means that one time frame cannot overlap multiple days. We understand your thinking that "11:00 to 1:00" should make sense, because you have checked all days. But if you think about constellations where someone checks only "Monday" then "11:00 to 1:00" is ambiguous, because it is unclear if Sunday 11:00 to Monday 1:00, or Monday 11:00 to Tuesday 1:00.

Set up your time frame conditions, so they do not overlap days. You can set up multiple time frame conditions to achieve this.
1. profile: 01:00 - 10:59
2. profile: 11:00 - 23:59 + 00:00 - 00:59

Offline