Invalid data type for 'BusType' / Bug Reports / NetSetMan Support

NetSetMan Support

Search for already answered questions about NetSetMan (Pro) or ask new ones

You are not logged in.

#1 2016-11-17 08:26

itpapa2
Member
Registered: 2016-11-17
Posts: 1

Invalid data type for 'BusType'

When I click on the netsetman icon inside the system tray it's opened a window with the message error specified in the subbject (Invalid data type for 'BusType').

Windows 7 64bit
NetSetMan 4.3.0
NSM activated

Thanks.

2016-11-17-08_22_57-NetSetMan.png

Offline

#2 2016-11-17 12:00

NetSetMan Support
Administrator
Registered: 2005-08-06
Posts: 1,878

Re: Invalid data type for 'BusType'

Thank you for posting this bug report!

We were notified about this bug by two other users after the release and already fixed it. This bug will only occur on a very low number of systems, because its cause is a non-standard configuration of a virtual network interface driver. That’s why we didn’t run into this problem in our own tests before the release and that’s also why there weren’t more users writing us about it. We don’t know how this driver configuration could happen in the first place, but of course it’s our duty to work around this problem.

The fix will be officially included in the next release, but we've also updated the current 4.3.0 version (same version number, but newer version date).
So please re-download the application from our website and intall it.

Offline